Thursday, 8 August 2019

F5 disconnect issues due to time mismatch

Working with the F5-LTM within a  device cluster ,  a "disconnect" issues are bound to always come up. 


One simple reason that's commonly over looked ; "if the devices time value are  far off , they two LTM will show a disconnected stated"


This will keep the two device device-trust from synchronizing since the  device-certificate would be to far spread between the two. NTP and clock-sync is a must within a F5-LTM.



Here's a typical f5-ltm  error for clock . This system is over 2+ years off.

Using the  unix date command ( from within the LTM bash shell )  we will adjust the system clock to the correct time. As soon as the time is corrected,  the  F5-LTM will reconnect and the disconnected status will vanish.